Green Construction Atlanta GA
Once you understand the basic concepts, healthy house construction is no more difficult than unhealthy house construction. However, it does involve more than just selecting non-toxic materials. It also requires an understanding of how a house functions - for example how a house "breathes" naturally (and why that may not be desirable), and how heating and ventilating systems interact.
Golder Associates, Inc.
770-496-1893
770-496-1893
3730 Chamblee Tucker Road
Atlanta, GA
Atlanta, GA
Jacobs Engineering Group, Inc.
770-673-6671
770-673-6671
One Concourse Pkwy.
Atlanta, GA
Atlanta, GA
SL King & Associates
404-524-5800
404-524-5800
South Tower, 225 Peachtree St. NE
Atlanta, GA
Atlanta, GA
CSE Engineering, LLC
404-343-0639
404-343-0639
4348 Abram Drive
Conley, GA
Conley, GA
JVG Civil Engineering
770-402-3471
770-402-3471
259 14th St.
Atlanta, GA
Atlanta, GA
Griffith Engineering, Inc.
770-451-6757
770-451-6757
4360 Chamblee Dunwoody Rd.
Atlanta, GA
Atlanta, GA
Grice & Associates, Inc.
404-577-6300
404-577-6300
1349 W. Peachtree St.
Atlanta, GA
Atlanta, GA
Spurlock & Associates Incorporated
404-633-0245
404-633-0245
2970 Clairmont Rd
Atlanta, GA
Atlanta, GA
Canterbury Engineering Incorporated
770-458-4882
770-458-4882
1057 Vijay Drive
Chamblee, GA
Chamblee, GA
Green Construction
A 14-point Plan for Healthy House ConstructionBy John Bower 1. Do build in a clean locale Site selection is the first consideration in healthy house construction because if the outdoor air quality is poor, then the indoor air quality will be poor also. It is possible to install filtration equipment to clean all of the air indoors, but this can be expensive. While filtration may be necessary in some instances, it is often easier to build in an unpolluted area in the first place. 2. Do build an airtight structure An airtight structure will minimize the amount of uncontrolled infiltration. This not only improves energy efficiency, but when coupled with a mechanical ventilation system, it gives the occupants maximum control over the indoor air. When outdoor pollution is occasionally high (e.g., neighbors applying lawn chemicals), the ventilation system can be temporarily shut off, and the indoor air will not be affected by the outdoor contaminants. An airtight structure also minimizes occupant exposure to insulating materials. 3. Do install a radon removal system It is difficult to predict if radon will be a problem in a particular house. The house must be tested for radon after it is built. It is easy to take some basic precautions in new construction, that may or may not need to be employed later. It is much more difficult to mitigate radon in a completed house if those precautions weren't taken initially. For example, a sub-slab piping system can be installed when the foundation is being built. If measured radon levels in the finished house are high, it will be a simple matter to hook up a suction fan to the piping. If radon levels are low, the system won't be necessary, and the sub-slab piping will remain unused. The expense should be considered low cost insurance. 4. Do install a ventilation system People need fresh air. Mechanical ventilation can supply that air at the correct rate whenever it is required. Relying on infiltration for the occupants' air supply is unreliable at best and, more often than not, insufficient. There are many approaches: supply ventilation through a fresh air duct to the return air side of a furnace, central exhaust, heat recovery ventilation, etc. The different systems have various advantages and disadvantages, but all can provide the occupants with fresh air. 5. Do use metal or solid wood cabinetry Kitchen and bathroom cabinets are... |
Click here to read the rest of this article from The Healthy House Institute

